skip to Main Content

Airmonte A8 Air Mattress System

Full Replacement Air System
Value, and Intuitive Operation

Description

Very High Risk Air System –

The Airmonte A8000 Mattress range embodies elevated levels in powered patient pressure care. Used and trusted in care facilities across Australia, the Airmonte provides high standard and consistency of care, with a flawless, easy to operate advanced designed at excellent value. Key clinical requirements including adjustable cell pressure, alternating/static modes, adjustable comfort level, low air loss, quick-release CPR valves, quality componetry, effortless operation and easy maintenance ensures effectiveness and comfort for patients and support for carers.

Features

Quality, Ergonomic Pump Unit

  • Styling is compact and efficient, ergonomically designed with an easy to operate panel.
  • Quality componentry.
  • Very quiet pump operation.
A8 Quality, Ergonomic Pump Unit

Pump Control Panel Functions

  • Cell pressure auto-adjusts to exactly suit patient, providing sepcialised pressure care.
  • Cycle time variable – 10, 15, 20, 25 minutes.
  • Comfort level adjustable and auto-firm inflation.
  • Alternating/static option.
  • Auto-adjusts seat function for stability when patients are sitting or changing.
  • Automatically controls mattress low air-loss feature, removing internal heat entrapment and patient perspiration.
  • Low pressure indication and power failure alert.
  • Panel lock facility.
A8 Pump Control Panel Functions

Alternating Cell Construction

  • 17 interchangeable alternating cells providing excellent pressure re-distribution.
  • Patient is supposed constantly, simultaneously allowing oxygen flow to all critical areas, preventing and/or healing pressure sores.
  • Height of mattress (20.3cm) allows maximum patient immersion for effectiveness and comfort.
  • Strengthened flexible TPU construction maintains mattress integrity for longevity and consistency of patient care.
  • Light overall weight (9kg) allows ease of set-up and transportation.
360 Integrated Zipper

Ventilated Cells

  • 16 ventilated cells in the centre region optimise micro-climate conditions at the patient interface, reducing excessive heat and moisture.
A8 Ventilated Cells

Power Cord Safety Retention System

  • Integrated loops enable the power cord to be fastened to the side of the mattress.
  • Prevents trip hazards and power cord entrapment by adjustable bed surface.
  • Press-stud closure allows easy fitment.
A8 Power Cord Sfaety Retention System

Modular Design

  • Every component is modular and replaceable for low ongoing operational costs.
  • 360° access zipper for ease of maintenance.
360 Integrated Zipper

Easy to Access CPR

  • Positioned on air supply tubes.
  • Access is not impeded by bed linen or side rails.
A8 Easy to Access CPR

360° Integrated Zipper

  • Allows full removal of upper cover.
  • Facilitates washing/laundering.

Combination Pressure Care Cover

The Combination Pressure Care Covers are a tried and proven medical grade pressure relieving cover. Utilising premium quality medical grade fabrics, the Combination Covers are the standard covering option across much of the Support Surface Range. Belgium made polyurethane coated upper and heavy duty PVC base ensures that the Combination Cover delivers consistent care, comfort and durability.

Zephair Premiflex Cover Icons

Combination Pressure Care Cover

Polyurethane Coated Pressure Care Upper –

  • 4-Way stretch for shear protection.
  • Vapour permeable and breathable.
  • Flexible and gentle to the skin.
  • Fire retardent, meets BS 6807 ignition source 5  and BS 7175 ignition source 5 standards.
  • Anti-microbial protection, resistant to patient body fluid.

Heavy Duty PVC Base –

  • Durable.
  • Protects foam core against the bed base.
  • Provides exceptional conformity and profiling to medical bed surfaces.
  • Reduces shearing forces by sliding against bed base as the bed profiles.
  • Meets fire retardant specifications: ASTM D6413 PASS, AS1441.13-1973 – PASS, AS1530.3-1999 – 14,0,0,5.

Integrated Zipper –

  • Allows easy cover removal.
  • Robust and durable.

Waterfall Zipper Protection Flap –

  • Protects against fluid ingress at point of zipper.
  • Meets infection control guidelines.

High Frequency Sealed and Welded Seams –

  • Electromagnetically fused seams protecting against risk of penetration of fluid.
  • Meets and exceeds infection control requirements.
  • Reinforced with additional heavy duty stitching at stress points.
  • 100% sealed to prevent ingress of fluid or infection.

Cleaning and Care –

  • 1000ppm disinfection chemical suitability.
  • Wipe clean.

Integrated Pressure Relief System –

  • Fitted standard to fully sealed and enclosed covers.
  • Relieves internal strain on cover seams.
  • High frequency welded to cover fabric.
  • Positioned unobtrusively for patient comfort.

Optional – Full Sealed and Enclosed –

  • Ultimate core durability and protection, protects foam core against willful damage.
  • 100% waterproof seams to prevent ingress of fluid and infection.
  • High frequency sealed and welded seams.

Pressure Care Fabric Colour Options –

  • Blue (standard colour)
  • Maroon
  • Green
  • Beige
  • Dark Blue
  • Grey

Premiflex Ultra Pressure Care Cover

The Premiflex covers are a superior choice for pressure relief and patient care. These covers use a selected range of proven pressure relief fabrics based upon their performance, care and longevity in the acute and long-term care setting. Premiflex grade covers are differentiated by their superior performance materials, heavier weight fabrics, increased shear protection, greater resistance to cleaning agents and superior durability within the acute care setting.

Zephair Premiflex Cover Icons

Zephair Premiflex Cover

Premium Polyurethane Coated Pressure Care Upper –

  • Superior 4-way stretch for shear protection.
  • Vapour permeable and breathable.
  • Flexible and gentle to the skin.
  • 10,000ppm cleaning agent concentration suitability.
  • Fire retardant, meets BS 6807 ignition source 5 and BS 7175 ignition source 5 standards.
  • Anti-microbial protection, resistant to patient body fluids.

Heavy Double Coated Polyurethane Base –

  • Durable.
  • Protects foam core against the bed base.
  • Provides exceptional conformity and profiling to medical bed surfaces.
  • Meets fire retardant specifications: BS EN 597-1: 1995, BS EN 597-2: 1995, BS 7175: 1989 ignition source 0,1,5.

Integrated 360° Zipper –

  • Allows easy cover removal.
  • Robust and durable.
  • High frequency welded attachment for optimal protection against fluid ingress.

Carry Handles –

  • Fits to side of mattress cover for easy access whilst mattress is on the bed.
  • Internal reinforcement for longevity.
  • Close mount design significantly reduces the risk of getting caught on other patient care equipment.
  • Fully sealed non-absorbent and wipe-clean for infection control.
  • Very strong and flexible for performance and durability.

High Frequency Sealed and Welded Seams –

  • Electromagnetically fused seams protecting against risk of penetration of fluid.
  • Meets and exceeds infection control requirements.
  • Reinforced with additional heavy duty stitching at stress points.
  • 100% sealed to prevent ingress of fluid or infection.

Specifications

Mattress Specifications –

Dimensions Length: 1980mm
Thickness: 150mm
Width: 870mm
Effective Support Loading (ESL)* 200kg

*Optimal patient weight ranage for pressure care and comfort.

Pump Specifications –

Dimensions Length: 290mm
Height: 150mm
Width: 310mm
Weight 3.4kg
Power Supply AC 120V, 60Hz (for 120V system)
AC 230V, 50Hz/60Hz (for 230V system)
Pressure Range adjustable 10 level (30 approx./equal 60mmhg)
Cycle Time variable: 10, 15, 20, 25 minutes

Downloads

Enquiry

Product Enquiry

"*" indicates required fields

Sign up for email newsletters
This field is for validation purposes and should be left unchanged.
Back To Top