Pure Air 8 Pressure Relief Mattress

The Pure Air 8 mattress is an advanced solution for patients at very high risk of pressure injuries. This dynamic, full-replacement system provides true auto-reactive pressure redistribution, adapting seamlessly to movement and weight. Its innovative design ensures exceptional stability, shock absorption, and comfort, promoting restful sleep and reliable high-risk patient care.

For more information contact Urgoform on 1300 369 096 or enquire below.

Description

The Pure Air 8 mattress is an advanced solution for patients at very high risk of pressure injuries. This dynamic, full-replacement system provides true auto-reactive pressure redistribution, adapting seamlessly to movement and weight. Its innovative design ensures exceptional stability, shock absorption, and comfort, promoting restful sleep and reliable high-risk patient care.

Product Specifications:

  • Product Code: SM013A
  • Weight Limits: No minimum, maximum of 250kg (39 stone)
  • Mattress Weight: 11kg
  • Cover Material: Polyurethane-coated multi-stretch nylon
  • Dimensions (inflated): 2000 x 880 x 205mm
  • Cells: 23 (3 static head cells, 20 alternating cells)
  • Control Unit Dimensions: 180 x 390 x 145mm
  • Available Sizes: Single, King Single, Double

Key Features & Benefits

  • Intelligent Self-Regulation: Automatically adjusts pressure in real-time, reducing caregiver workload while ensuring optimal pressure relief for patients.
  • Four Operation Modes: Provides versatile care with Constant Low Pressure for better support, Alternating mode for pressure redistribution, Pulsation for tissue stimulation, and Max Inflate for stability during transfers or procedures.
  • Zoned Surface Design: Static head cells enhance stability and comfort, while narrow heel cells offer tailored support for lighter areas, improving patient comfort.
  • Patient Egress Alert: Notifies caregivers when the patient leaves the bed, enhancing safety and reducing risks.
  • Constantly Inflated Sub-Cell: Minimises the risk of “bottoming out,” ensuring reliable support for patients.
  • Automatic Function Lockout: Prevents accidental adjustments by locking controls after two minutes, maintaining consistent settings.
  • Power Failure & Low Pressure Alerts: Immediate visual and audio notifications ensure swift responses, guaranteeing uninterrupted care.

Specifications

Product Code SM013 (Alternating/Static version), SM013C (Alternating/CLP version)
Minimum Weight Limit No minimum
Maximum Weight Limit 225kg (35.5 stone)
Cover Material Polyurethane coated multi-stretch nylon
Mattress Dimensions (inflated) (L) 200 x (W) 90 x (H) 20 cm
Control Unit Dimensions (H) 20 x (W) 28 x (D) 10 cm
Number of Cells 20 fully alternating
Inflated Cell Height 20 cm
Alternation Cycle 1 in 2
Initial Inflation Time 30 – 45 mins

Brochure

Pure Air 8 Brochure

Enquiry

Product Enquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Sign up for email newsletters

Warranties & Standards

Compliance with Relevant Standards 

The Pure Air 8 Mattress has been tested to and complies with the following standards:

  • EMDN Code & Term – V080701 Active anti-bedsore medical mattresses
  • Risk Classification – Risk Classification: Class I medical device according to the regulation (EU) 2017/745, Annex VIII, rule 1
  • Harmonised Standards Applied – EN ISO: 13485:2016, 14971:2012, 15223-1:2016, 10535:2006
  • Basic UDI-DI – 50564619DYN_PUP3N
  • Quality Management System – ISO-13485-2016
  • Safety Standards – BS EB 60601-1:2006+A13:2024
    IEC 60601-1-11, IEC 60601-1-2, BS EN 61000, IEC 61000-3-3, IEC 61000-3-2, IEC 61000-4-2, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11, IEC 61000-4-8, IEC 61000-4-6, IEC 61000-4-3
  • Biocompatibility Standards (Skin & Patient Contact) – SO 10993 series — Biological evaluation of medical devices, ISO 10993-1: Evaluation and testing within a risk management process, ISO 10993-5: Tests for in vitro cytotoxicity, ISO 10993-10: Tests for irritation and skin sensitization, ISO 10993-23: Tests for irritation (skin and mucosal surfaces)
  • Infection Control & Hygiene – ISO 16603 / ISO 16604 — Resistance of materials to penetration by blood and body fluids / blood-borne pathogens, EN ISO 22610 — Resistance to wet bacterial penetration (commonly referenced alongside UNI EN 13795), EN ISO 22612 — Resistance to dry microbial penetration, ISO 14272 (and related) — Cleanability and disinfectant resistance
  • Flammability Standards (Hospital Safety) – BS 7175 — Flammability testing for bed mattresses and components used in hospitals (UK/NHS standard), Crib 5 / Source 5 test — Specific ignition resistance test (often cited in Australia & UK healthcare tenders), CAL TB 129 (California Technical Bulletin) — Full-scale flammability test for mattresses, EN 597-1 & EN 597-2 — Smouldering cigarette and match flame tests
  • Performance & Durability – SO 12947 (Martindale Test) — Abrasion resistance of fabrics, ISO 811 — Hydrostatic head test (liquid barrier performance), ISO 14126 — Protective clothing against infective agents (often adapted for mattress covers in clinical use), EN 13795 (for surgical textiles, sometimes referenced in infection-barrier bedding)
ARTG Certificate: 363471

 

Warranty:

  • Mattress Internal Components – Three Years
  • Cover – Three Years
  • Pump – Three Years
  • Clinical Service Life (Normal Use) – Six Years

Disclaimer

All product descriptions, indications or advice found on this website are to be used as a guide only, and are by no means a substitute for professional medical advice. Proper use of medical devices requires diagnosis by a physician or physical therapist. Urgoform accepts no responsibility for the improper or uninformed use of it’s products.

urgoform-slogan-150

CALL 1300 369 096

MELBOURNE SHOWROOM
45 Bayside Avenue
Port Melbourne VIC 3207

GEELONG SHOWROOM
5-7 Tarkin Court
Bell Park VIC 3215

MON to FRI 8AM – 4.30PM
BY APPOINTMENT ONLY

ABOUT URGOFORM

EQUIPMENT SOLUTIONS

ndis-logo
Back To Top