Ultimate Comfort, Superior Care.
The ZEPHAIR pressure air mattress provides true leadership in powered patient pressure care. Tried and trusted in facilities from ICU wards to palliative hospice use, this pressure care system will provide the answer to all acute care needs, whilst providing unparalleled comfort and staff primary care compliance. Key clinical attributes include ventilated immersion upper layers, deep 24 cell alternating integrated inner mattress core, firm base foam layer, quiet efficient airflow generator with easy set weight calibration and dual stretch waterproof breathable cover.
The ZEPHAIR pressure care air mattress range includes models suited for standard hospital bed sizing, wide & bariatric requirements. The quality and features of the Zephair mattress allows confident usage
in the hospital, aged care and spinal environments.
Features
24 Cell, Alternating Air System
- 125mm depth facilitates immersion.
- Ultra-flexible, soft-touch material.
- 24 Cell Sytem minimises patient disturbance.
- Static head support region.
Multi-Tiered Shear Reduction System
- Low friction inner cover compartmentalised to segregate the modular regions of the Zephair in turn delivering a series of shear reduction levels.
- Provides patients with fragile and frail skin additional protection and preventative care.
Silent, Ergonomic Pump
- Silent operation minimising patient disturbance.
- Intuitive, simple operation.
- One-touch quick-change air filter for ease of maintenance.
- Mounts to wide variety of beds.
- Quality componentry.
- Full after-sales backup and support.
- Low pressure indication and power failure alert.
Power Cord Safety Retention System
- Integrated loops enable the power cord top be fastened to the side of the mattress.
- Prevents trip hazards and power cord entrapment by adjustable bed surface.
- Press-stud closure allows easy fitment.
Easy to Access CPR
- Positioned on air supply tubes.
- Access is not impeded by bed linen or side rails.
Modular Design
- Every component is modular and replaceable for low ongoing operational costs.
- 360° access zipper for ease of maintenance.
Patient Interface – Lower Layer
- High-performance, memory immersion foam.
- Alleviates localised pressure points.
- Provides maximum contact with patient for distribution of interface pressure.
- High temperature stability to deliver consistent immersion, performance and comfort.
- Unique airo-form ventilation system minimises heat entrapment and enhances core circulation providing a cooler sleep surface.
- Visco-elastic cell structure provides low-shear surface.
Firm Foam Base Layer
- Provides protection to air system from bed base.
- Provides patient protection should a prolonged power outage accur.
Profile Stabilising Sides
- Enables ease of primary patient care.
- Facilitates patient transfers.
- Unique hinge points allow mattress to easily conform to varied bed positions.
- Encourages central patient positioning.
Sloped Heel Region
- Enhances pressure relief and protection for critical at-risk heel region.
- Offloads pressure from the patients heels and transfers it to the calf area.
- Unobtrusive, does not require any adjustment.
Premiflex Ultra Pressure Care Cover
Premium Polyurethane Coated Pressure Care Upper –
- Superior 4-way stretch for shear protection.
- Vapour permeable and breathable.
- Flexible and gentle to the skin.
- 10,000ppm cleaning agent concentration suitability.
- Fire retardant, meets BS 6807 ignition source 5 and BS 7175 ignition source 5 standards.
- Anti-microbial protection, resistant to patient body fluids.
Heavy Double Coated Polyurethane Base –
- Durable.
- Protects foam core against the bed base.
- Provides exceptional conformity and profiling to medical bed surfaces.
- Meets fire retardant specifications: BS EN 597-1: 1995, BS EN 597-2: 1995, BS 7175: 1989 ignition source 0,1,5.
Integrated 360° Zipper –
- Allows easy cover removal.
- Robust and durable.
- High frequency welded attachment for optimal protection against fluid ingress.
Carry Handles –
- Fits to side of mattress cover for easy access whilst mattress is on the bed.
- Internal reinforcement for longevity.
- Close mount design significantly reduces the risk of getting caught on other patient care equipment.
- Fully sealed non-absorbent and wipe-clean for infection control.
- Very strong and flexible for performance and durability.
High Frequency Sealed and Welded Seams –
- Electromagnetically fused seams protecting against risk of penetration of fluid.
- Meets and exceeds infection control requirements.
- Reinforced with additional heavy duty stitching at stress points.
- 100% sealed to prevent ingress of fluid or infection.
Specifications
ZAS1000 Single Sizing | Length: 1980mm Thickness: 215mm Width: 880mm |
ZAS1000 King Single Sizing | Length: 1980mm Thickness: 215mm Width: 1050mm |
Effective Support Loading (ESL) | 30 – 180kg |
Warranty* | Foam Core – 5years Pump – 1year Air Cell System – 2years |
ESL – optimal patient weight range for pressure care and comfort.
*Warranty refers to any manufacturing or product defects. Due to its nature, foam will soften and its resilience will decrease with usage and age.