Skip to content

Pure Air 120

Pure Air 120 pressure care mattress immerses and offloads the user by operating at industry-leading internal cell pressures. Combined with a pioneering figure of 8 air cell design and cell inflation technology that provides a unique cell inflation changeover. Pure Air 120 user comfort is optimised thanks to low interface pressure and smooth surface movement.

Description

Pure Air 120 pressure care mattress immerses and offloads the user by operating at industry-leading internal cell pressures. Combined with a pioneering figure of 8 air cell design and cell inflation technology that provides a unique cell inflation changeover. Pure Air 120 user comfort is optimised thanks to low interface pressure and smooth surface movement.

Increased patient safety is achieved thanks to the sophisticated and simple to understand system of integrated alerts. The intuitive control unit delivers therapy quietly and consistently. Supporting even the most vulnerable with their rest and sleep.

Durable materials and surface and cover that can be cleaned and decontaminated. Allowing consistence maintenance throughout the life of the mattress.

Key Features & Benefits

  • Industry-leading low interface pressures provide effective pressure redistribution, via immersion and off-loading, due to optimal internal cell pressures.
  • Improve patient safety and concordance with a stable platform, with shock absorber-like support that doesn’t bend or slip, due to the pioneering figure of 8 air cells with i-Beam.
  • Optimise patient comfort with cells that alternate across the full width of the mattress.
  • Patients can rest easy and sleep effectively due to the smooth movement within the surface which supports patient comfort owing to a cell changeover pattern like no other.

Specifications

Product Code PUR-120
Mattress Dimensions (inflated) (L) 200 x (W) 120 x (H) 20 cm
Minimum Weight Limit 60 kg
Maximum Weight Limit 298 kg
Control Unit Dimensions (L) 28 x (W) 11 x (H) 20 cm
Max Inflate Auto-return to therapy after 20 mins
Pressure Adjustment Semi-automatic
Cell cycle Time 10, 15 mins
Pressure Adjustment Semi Automatic
Alerts Audible low pressure alert with alert mute

Brochure

Pure Air 120 Brochure

Enquiry

Product Enquiry

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Sign up for email newsletters

Warranties & Standards

Compliance with Relevant Standards 

The Pure Air 120 Mattress has been tested to and complies with the following standards:

  • EMDN Code & Term – V080701 Active anti-bedsore medical mattresses
  • Risk Classification – Risk Classification: Class I medical device according to the regulation (EU) 2017/745, Annex VIII, rule 1
  • Harmonised Standards Applied – EN ISO: 13485:2016, 14971:2012, 15223-1:2016, 10535:2006
  • Basic UDI-DI – 50564619DYN_PUP3N
  • Quality Management System – ISO-13485-2016
  • Safety Standards – BS EB 60601-1:2006+A13:2024
    IEC 60601-1-11, IEC 60601-1-2, BS EN 61000, IEC 61000-3-3, IEC 61000-3-2, IEC 61000-4-2, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11, IEC 61000-4-8, IEC 61000-4-6, IEC 61000-4-3
  • Biocompatibility Standards (Skin & Patient Contact) – SO 10993 series — Biological evaluation of medical devices, ISO 10993-1: Evaluation and testing within a risk management process, ISO 10993-5: Tests for in vitro cytotoxicity, ISO 10993-10: Tests for irritation and skin sensitization, ISO 10993-23: Tests for irritation (skin and mucosal surfaces)
  • Infection Control & Hygiene – ISO 16603 / ISO 16604 — Resistance of materials to penetration by blood and body fluids / blood-borne pathogens, EN ISO 22610 — Resistance to wet bacterial penetration (commonly referenced alongside UNI EN 13795), EN ISO 22612 — Resistance to dry microbial penetration, ISO 14272 (and related) — Cleanability and disinfectant resistance
  • Flammability Standards (Hospital Safety) – BS 7175 — Flammability testing for bed mattresses and components used in hospitals (UK/NHS standard), Crib 5 / Source 5 test — Specific ignition resistance test (often cited in Australia & UK healthcare tenders), CAL TB 129 (California Technical Bulletin) — Full-scale flammability test for mattresses, EN 597-1 & EN 597-2 — Smouldering cigarette and match flame tests
  • Performance & Durability – SO 12947 (Martindale Test) — Abrasion resistance of fabrics, ISO 811 — Hydrostatic head test (liquid barrier performance), ISO 14126 — Protective clothing against infective agents (often adapted for mattress covers in clinical use), EN 13795 (for surgical textiles, sometimes referenced in infection-barrier bedding)
ARTG Certificate: 363471

 

Warranty:

  • Mattress Internal Components – Three Years
  • Cover – Three Years
  • Pump – Three Years
  • Clinical Service Life (Normal Use) – Six Years

Disclaimer

All product descriptions, indications or advice found on this website are to be used as a guide only, and are by no means a substitute for professional medical advice. Proper use of medical devices requires diagnosis by a physician or physical therapist. Urgoform accepts no responsibility for the improper or uninformed use of it’s products.

urgoform-slogan-150

CALL 1300 369 096

MELBOURNE SHOWROOM
45 Bayside Avenue
Port Melbourne VIC 3207

GEELONG SHOWROOM
5-7 Tarkin Court
Bell Park VIC 3215

MON to FRI 8AM – 4.30PM
BY APPOINTMENT ONLY

ABOUT URGOFORM

EQUIPMENT SOLUTIONS

ndis-logo
Back To Top